WHICH LOCAL CODE ITEMS MUST BE ON AN OFFICIAL FIRE MARSHAL CHECKLIST?

Nine Kentucky items. Miss them and the citation is not a surprise.

First-Line technician checking the valve on two red fire extinguishers in the shop

Kentucky adopts the Kentucky Fire Prevention Code. In practice that means NFPA 1 (Fire Code) and NFPA 101 (Life Safety Code), plus the local amendments your city or county fire official enforces. The marshal is not inventing a list on the sidewalk. These nine items are what has to be on an official fire marshal checklist.

Bottom line up front

Nine mandatory items: exits and egress; emergency lighting; fire extinguishers; alarm and suppression; electrical safety; maximum occupancy; hazardous materials storage; written fire safety plans; construction permits. Missing them in Kentucky can mean $1,000+ fines and, on a bad day, a closed door until it is fixed.

How to get the binder and the floor ready is the companion 4 steps to pass your Kentucky Fire Marshal inspection.

Legal foundation

The state fire official and the local fire official share the Kentucky Fire Prevention Code. NFPA 1 sets fire-protection and hazard rules. NFPA 101 sets how people get out. Your occupancy — store, church, plant, kitchen, healthcare — changes the details, not the nine headings. Keep the reports. Keep the path clear. Keep up with the due dates on anything that has one.

1. Exits and egress

Requirement. Every required exit stays clear, unlocked in the direction of travel, and marked. Travel distance and occupant load have to match the occupancy.

What marshals verify. Marshals walk the path a customer would take. They open the door, check panic hardware, and look for stock in the aisle.

Common violations. A chained exit, a blocked stair, a storage pallet in the corridor, or an exit sign that points into a locked office.

We do not rebuild your doors. We will flag a blocked path when we walk the floor for extinguishers and lights.

2. Emergency lighting

Requirement. Emergency lights and exit signs must work on building power and on battery. Monthly functional checks and an annual 90-minute load test have to be logged.

What marshals verify. They kill a breaker or hit the test button and watch. They ask for the monthly log and the last 90-minute test.

Common violations. Dead batteries, a dark exit sign, no annual load-test record, or units that were never installed where the occupancy requires them.

That test is exit and emergency lights. We run it and leave the log in the binder.

3. Fire extinguishers

Requirement. The right class and size, mounted, visible, and serviced on the NFPA 10 interval. Annual maintenance is the professional visit. In between, somebody should look at every extinguisher once a month. Your people can do that, or we can walk it for you.

What marshals verify. They check the last inspection date, the gauge and the pin, and the travel distance to the next unit.

Common violations. An inspection that’s past due, a unit sitting on the floor, a blocked cabinet, or an ABC where the kitchen needed Class K.

Annual service, recharge, and hydro live on fire extinguishers.

4. Alarm and suppression

Requirement. Fire alarm inspection and testing per NFPA 72. Sprinklers per NFPA 25. Commercial kitchens need a listed hood system and the service records that go with it.

What marshals verify. They want the last inspection report, the monitoring account if you have one, and proof the hood system isn’t past due for service.

Common violations. A silenced panel, a missing report, a painted sprinkler head, or a fryer under a hood that has not been serviced.

Reports come from fire alarms and suppression systems. We can resend what we already filed.

5. Electrical safety

Requirement. Clear working space at panels (the three-foot rule). No daisy-chained extension cords as permanent wiring. Covers on boxes. Breakers labeled.

What marshals verify. They open the electrical room and look at the cords on the floor.

Common violations. A fridge plugged into a power strip, a panel used as a shelf, or a missing blank in the breaker space.

We are not the electrician. We will still call it out on a walk-through so it is fixed before the marshal sees it.

6. Maximum occupancy

Requirement. Posted occupant load where the code requires it. Exits and seating have to support that number.

What marshals verify. They count seats, look at the posted sign, and compare it to the exit width.

Common violations. A missing occupant-load sign, extra tables that blow the number, or an assembly space with one usable exit.

We do not set occupant load. We keep the exits lit and the extinguishers in reach for the load you already posted.

7. Hazardous materials storage

Requirement. Flammable liquids, gases, and other regulated materials stored in approved cabinets or rooms, with quantities and labels that match the occupancy.

What marshals verify. They look in the closet behind the shop and the cage by the dock.

Common violations. Open gasoline cans, unmarked drums, LPG next to an exit, or a quantity that belongs in a rated room.

If the hazard needs a special extinguisher or a suppression system, we match the unit. Storage construction is on your contractor.

8. Written fire safety plans

Requirement. A written plan for the occupancy: alarms, evacuation, meeting points, and who calls 911. Staff should be able to say it out loud.

What marshals verify. They ask for the plan and then ask an employee the same questions.

Common violations. No plan, a plan dated five owners ago, or a crew that cannot name the meeting point.

The huddle for R.A.C.E. and P.A.S.S. is on the four-step inspection prep page. Live practice, if you want it, is fire safety training.

9. Construction permits

Requirement. Work that changes exits, occupancy, suppression, or alarm systems needs the right permit and a final that matches what was built.

What marshals verify. They compare the floor to the last approved drawing.

Common violations. A wall that closed an exit, a kitchen line with no hood permit, or a mezzanine that never got reviewed.

We install and service the systems the permit called for. We do not sign the building permit.