For rooms where water would do more damage than the fire.

A sprinkler puts the fire out. It also soaks everything in the room. That’s fine in a warehouse. It’s not fine in a server room, a control room, or a room full of records.

Bright empty server-room aisle with rows of racks — no water on the servers

What these systems are

Instead of water, these systems fill the room with an agent that puts the fire out. We work on systems such as Halon, FM-200, and CO2.

Halon and FM-200 are clean agents. They leave nothing behind. There’s no water, no powder, and no cleanup. What’s in the room is still there when the fire’s out.

CO2 works differently. It pushes the oxygen out of the room, and a fire can’t burn without oxygen. That also means people can’t breathe in there, so everybody’s out before it goes. We match the system to the hazard.

How it works

Every system comes with an alarm. Detectors in the room pick up the fire. The panel sounds the alarm and counts down so people can get out. Then the cylinders release, and the agent fills the room.

That only works if the room holds the agent. If a door’s propped open, or somebody punched a hole in the wall for new cable, the agent leaks out before it can do its job. We look for that too.

What we check

  • The cylinders: weight and pressure.
  • The nozzles: clear, and pointed where they’re supposed to be.
  • The release path: the panel, the detectors, the abort switch, and the manual release.
  • The room: doors close, and nothing new has been cut through the walls or ceiling.
  • The warning signs: up, and where people will see them.

What a visit looks like

We walk the room, check the cylinders, nozzles, and release path, service what’s due, and leave a report.

These systems go on the same calendar as your extinguishers, alarms, and lights. We keep the due dates. You don’t have to think about them.

Who it’s for

Server and data rooms, control rooms, electrical rooms, records rooms, and plants. It fits anywhere water would do more damage than the fire.

If it releases

Once the system goes off, fire or not, that room isn’t protected until the cylinders are recharged. Call. Our 24-hour service covers releases.

Questions

What sets it off?
The detectors in the room, or somebody pulling the manual release. The alarm and the countdown give people time to get out first.
Do we have to leave the room when it goes off?
Yes. When the alarm goes, everybody leaves, no matter which system it is.
Can you take over a system somebody else put in?
Yes. We’ll walk it, tell you what shape it’s in, and put it on your calendar.

Areas we serve

Served from Paducah, Madisonville, and Princeton, IN. City pages:

Full service area

Call or request a quote.

Send the form and we will call you.

CALL NOWFree quote

We use cookies to keep the site working and to see which ads bring us customers. Cookies · Privacy Policy